ELECTRO SPINNING V2

Description Specification
Spinning Orientation Vertical or Horizontal to be specified while ordering.
High Voltage Power Supply
  • Variable from 0 to 40 KV
  • Resolution 0.1 KV
  • Max. Current 0.4mA
  • With Digital voltmeter & Microammeter for voltage and current display.
  • Overload and short-circuit protection
  • Safety interlock to shut down when door is opened
Syringe Pump 1
  • To dispense from 10 nos. of Standard Syringes
  • Fabricated using insulated material
  • Work under high voltage conditions and to
  • Programmable - HMI & PLC control
  • Flow rates 1uL/min to 20ml/min
  • Time and volume-based control
  • Direct syringe based spinning – without tubing
Syringe Pump 2 To dispense from 1 no. of Standard Syringes
All other specifications same as Pump 1
Coaxial spinneret
  • Spinneret for coaxial spinning
  • Chemical resistant Tubing to connect syringe with spinneret – 10 meters
Multi nozzle Multi nozzle spinneret with 5 needles geometry
Drum Collector Length 300 mm Dia 100 mm (Customizable)
Rotating Speed 500 – 4000 RPM
Disc Collector Dia 100 mm Thickness 5 mm
Plate Collector 300 x 300 mm (Customizable)
Distance Adjustment Motorized adjustment of distance between Syringe and Collector. 0 to 250 mm - X Axis
Syringe Translation Movement
  • Syringe pump mounted
  • Translation stage of 300mm (Y Axis )
  • Programmable speed and distance
Plate Collector Movement
  • Motorized movement of 300mm.
  • Digital display of rate of movement with speed control.
  • Provision for independent movement or linked with syringe translation pump stage.
Linked feature will make the Plate move for a defined short distance for each traverse of the syringe translation movement for uniform coating on the plate Independent mode will move the plate collector independent of the Syringe Translation Movement – There may not be a co-ordinate movement of the plate with the syringe.
Cabin Heating Temperature & Humidity Display
  • Provision to heat cabin up to 40°C
  • Digital Display of Cabin Temperature & Humidity
Electrospinning Enclosure Aluminum Strut frame with glass panel
Safety & Additional Features of Cabinet
  • Static removal device –Discharge Stick
  • H.V. Power supply off when door opened.
  • Hazard lamp to indicate that H.V. Power supply is on.
  • Cabin lighting
  • Back Light to view Needle tip
  • Exhaust Fan-ventilation
  • Rubber floor mat for user safety
OPTIONALS
  • Syringe Heater
  • Inert / Vacuum Chamber
  • Mini Chamber to spin with static collector under inert gas or vacuum.
  • Dehumidifier / humidifier
  • Cocoon collector
  • Parallel Plate collector
  • Rod collector – to fit rods from 1 to 25 mm
  • Drum collector available in different diameters from 25 to 100mm

Helpline and Support

+91 44 43302775

Please Contact And We’ll
Do Our Best To Help.

Request Now
back top